Woson Tanco 8 L Type D with Class B medical printer
Woson is a famous manufacturer of high-quality medical and cosmetics. Brend provides beauty parlors, tattoo studios, hospitals and clinics with professional equipment used in the sterilization process, thereby maximizing safety and hygiene for the people conducting the procedures and their clients.
Safe sterilization of a wide range of instruments.
Woson New Tanco 8 l is an indispensable tool that will work well in any beauty, manicure salon and other places where it is important to preserve the sterility of the tools used during the procedures.
The sterilization in the upper-class B medical unit ensures the full efficiency and safety of the process, which contributes to maintaining high standards of hygiene in the office. The equipment is designed to sterilize both medical and non-medical tools, packed and unpacked, uniform, in-depth A and porous items. Only qualified personnel with knowledge and appropriate training in the operation of this type of equipment may operate the device.
Functional control
Open a light panel to control the display, you may be switched between programmes, constructions and contact data. The process will be read and real. Thermoprinter can be used to replace thermo-strun. Sterilization where information such as: date and time of the cycle, temperature and pressure changes can be found. In this case, the front door should be replaced. The printer can be connected to USB-port. Protect the results of sterilization in the digital video on the flash card, return it to the kit. Open the boilers and the water pump. It's a function of water flow control. This information system provides information on your whereabouts where it is. That's why the door doesn't turn. If you don't have to worry about water damage, it'll be damaged. There's a risk of damage.
Sterilization, testing and treatment programmes are available.
The autoclave is programmed to: 4 sterilization programmes, 2 testing programmes to perform three tests: vacuum test, BD test and Helix test, regular tube maintenance and treatment programme (train purification) and drying programme (drive function). This allows for the identification of parameters for individual needs and the preparation of a party. It is also possible to establish and maintain their own sterilization parameters on a case-by-case basis.
STERILIZATION PROGRAMME
Sterilization programme Type of load Temperature Pressure Coherence of the vacuum Cycle time
“STACKED”
” The programme is designed to sterilize unpacked items. 134 °C 210 kPa 1x sterilization time: 4 minutes; drying time: 9 minutes
" PACKGROUND
” The programme is designed to sterilize packed items and boards. 134 °C 210 kPa 3 times sterilization time: 5 minutes; drying time: 9 minutes
PRION
" PERSONS " Programme designed to injection, bacteria and viruses, etc. 134 °C 210 kPa 3 times sterilization time: 18 minutes; drying time: 9 minutes
" FURTHER "
" FURTHER " Programme for the sterilization of cotton and similar products. 121 °C 110 kPa 3 times sterilization time: 20 minutes; drying time: 18 minutes
Sheet
medical class B The most modern sterilizers to sterilize unpacked and packaged items as efficiently as possible, regardless of the type of instrument. They are distinguished by the establishment of a factional pre-vacuum.
Legal requirements The device is certified CE 0197 and complies with the requirements of Directive 93/42/EEC on Medical Devices and Directive 97/23/EC. It also conforms to EN 61010-1; EN 61010-2-040; NE 13060; EN 61326-1. The manufacturer has certificates EN ISO 9001 and EN ISO 13485.
8 litres Perfect for beauty parlors and clinics. It contains a basket with three lots on which packaged and unpacked tools can be located.
Intended printer Thermobum is used to avoid problems related to the replacement of ink.
Sterilizing the tools with a dip or a pack. Both methods of sterilization are very effective.
Light Display control It makes it easy to select a suitable programme and set parameters. During the process, it displays temperature, pressure and time.
8 automatic programmes 4 sterilization programmes, 2 testing programmes, 1 cable treatment programme, 1 drying programme.
Build tanks for distilled and used water. The clean water reserve is intended for distilled or deionized water for sterilization. The availability of a wastewater tank means that there is no need for an additional outer container.
Self-diagnosing system Sensible messages help to avoid damage.
Steel cam The material used is for medical use and longevity, which proves the quality of the device.
Compliance with the requirements of Sanepidnadsor No registration is required in the Office of Technical Oversight.
Technical passport It fits.
Safeguards 24 months. The guarantee period does not depend on the number of cycles completed.
Technical data
Certifications and standards CE 0197 (93/42/EEC, 97/23/EC),
EN 61010-1; EN 61010-2-040; EV 13060; EN 61326-1
Power 1,600 W
Nominal voltage 220 In variable current ~ 240 in AC, 50 Hz ~ 60 Hz
Maximum operating temperature 145°C
Maximum working pressure 2.5 bar (250 kPa)
Minimum working pressure -0.9 bar (90 kPa)
Time adjustment 20 to 60 minutes for programme at 121 °C or 4 to 20 minutes for programme at 134 °C
Coffee time 0 to 60 minutes, 5 minutes
Ratio of vacuum 1x, 3x or 5x
Package size 652 x 549 x 486 mm
External dimensions 545 x 382 x 375 mm
Camera material stainless steel
Cell size 251 x 137 x 132 mm