Lafomed Premium Line LFSS08AA LCD 8 l, Class B
High-quality carclaves
Lafomed is a brand of high-level carclaves recognized in more than 50 countries around the world. Autoclaves meet all health standards and directives. These devices have a low rate of rejection. Their microprocessors use electronic modules of the last generation. Lafomed autoclaves are highly efficient and durable, and their management is simple and intuitive.
APPOINTMENT:
LFSS08AA LCD autoclave is designed to sterilize invasive medical products. The device helps prevent cross-contamination. The car is specially designed for hospital offices, dental units, ophthalmological offices and biological research institutes. Designed to sterilize surgical instruments, dental instruments, syringes, etc. Applicable for the sterilization of packed (one- and multi-layer) and unpackaged solids, porous articles and articles according to EN 13060:2004+. Standard A2: 2010. Autoclaves can also be used for non-medical and veterinary purposes.
Attention: The device is not designed to sterilize liquid substances.
High-grade car.
The Lafomed series Premium Line is particularly recommended for hospital offices, dentals and ophthalmology, as well as for the biological institutions carrying out research projects. It's perfect for hairdresser and salon beauty, tattoo studio and aesthetic medicine salon. The machine is designed to sterilize both medical and non-medical instruments. Activeshop, created by special order, has functions that are not available in other autoclaves, making this product particularly unique. The sterilization in the upper-class B medical unit ensures full efficiency and safety.
Functionality you appreciate
It's a compact device combining autoclaves and a built-in thermal printer. It has HC-dipples and USB-port, which allows the data carrier to be connected to maintain the cycle results. There are 10 fully automatic programmes ; 7 sterilization programmes, 2 testing programmes and the autoclave clean-up programme. In addition, it also has a user programme that ensures full freedom of choice of parameters. The menu is intuitive and a friendly interface in Polish. Pre-heating and heat maintenance functions will also be useful. Lafomed Premium Line cart is characterized by rapid sterilization programmes with the ability to control drying time. The shortest sterilization and drying programme lasts only seven minutes. The apparatus contains an integrated clean (distilled) water tank, which is used for sterilization, and a waste water tank that can be discharged from the front or rear of the apparatus. The self-diagnosing system will effectively protect the debris and maintain the durability of the device. Additional security will provide a double lock system.
Automatic sterilization programmes
Sterilization programme Pressure Total cycle time*
121° Uniform 110 kPa 23 minutes
121° Shouting 110 kPa 27 minutes
121° 110 kPa 30 minutes
134° Equal 210 kPa 7 minutes
134° Shouting 210 kPa 11 minutes
134° 210 kPa 14 minutes.
135° Princess 210 kPa 29 minutes
* Recorded to time after heating the device.
Sheet:
medical class B This is the top class of autoclaves, allowing for the most effective sterilization of unpackaged and packaged items, irrespective of the type of instrument.
High quality The carclave is constructed according to ISO 13485 and has a CE 1023 certificate. It also meets the requirements of European standard BS EN 13060:2014+A1:2018.
8 l The 8-litre machine is perfect, for example, for the beauty parlor or tattoo salon. We'll put a bar with three lots in the cell.
Intended printer
Thermal is not required by the use of the thermobum.
Sterilizing the tools with a dip or a pack. Class B carclave allows sterilization of both unpackaged and packaged instrument (massive or semi).
FC Display Specify time, temperature, pressure and running.
Simple and effective management The intuitive menu allows for the rapid selection of the programme or the setting of parameters, and a suitable interface is in Polish.
10 automatic programmes 7 sterilization programmes, 2 testing programmes; Bowie and Dick, as well as a vacuum testing and treatment programme.
Short sterilization The fastest program lasts seven minutes, including the cushion. The carclave is also able to control the drying time.
User programme The carclave allows you to identify your own sterilization program and to set all parameters.
Cleaning programme Designed to clean the carclave. It is particularly noticeable that the message " TREBUETS BOYSKA " appears.
USB-port Keep digital data on the flash drive and don't worry about the loss or damage to the valuable evidence you need.
Hash Function The last sterilization programme implemented will be remembered and easily accessible after the autoclave is activated.
Launch vehicle function Thanks to this function, you will launch the program in advance. You can set the delayed launch of the programme at a given date and time or at any number of hours later.
Pre-heating function
When this function is activated, the device shall be preheated before the programme or parameters are installed.
Temperature maintenance function The autoclave will heat the chamber and activate the vapour generator to maintain a constant heat temperature (maximum 8 hours). This reduces the time required to complete each cycle of sterilization.
Busted for clean and used water. The clean water reserve is intended for distilled or deionized water to be used for sterilization. The availability of a wastewater tank means we don't need to remember the outer receptacle.
Self-diagnosing system Effective protection against damage.
Stainless steel camera 304 This makes it extremely strong and aesthetic, and proves the quality of the device.
Double door lock Enhanced system providing mechanical and electronic door protection.
Compliance with the requirements of Sanepidnadsor No registration is required in the Office of Technical Oversight.
Safeguards 24 months with a possibility of extension for another 12 months.